C5354 (bizhub C554e/C454e)

You are here:

Contents

Trouble typeOzone fan failure to turn
Trouble codeC5354
RankB
Detection timingThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary.
Trouble isolation
Relevant electrical parts• Ozone fan (FM13)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between FM13-relay CN165-PRCB CN23 for proper connection and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM13 operation checkPRCB CN23-10 (REM)PRCB CN23-12 (LOCK)5-C
4Replace FM13 (Part# A03UM15300)
5PRCB ICP19 conduction check
6Replace PRCB (C554e Part# A5AYH00101 / C454e Part# A5C0H00101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.5 (Link to the Field Service Manual)