Trouble type | Ozone ventilation fan’s failure to turn |
Trouble code | C5354 |
Rank | B |
Detection timing | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -Ozone ventilation fan motor (FM6) -Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between FM6-relay CN322-PRCB CN1 for proper connection and correct as necessary. | – | – |
2 | Check the fan for possible overload and correct as necessary. | – | – |
3 | FM6 operation check | PRCB CN1-6 (DRIVE)PRCB CN1-8 (LOCK) | 7-K |
4 | Replace FM6 (Part# 9313100072) | – | – |
5 | Replace PRCB (Part# A2X0H00102) | – | – |