C5358 (bizhub 554e/454e)

You are here:

Contents

Trouble typeFusing power supply cooling fan’ss failure to turn
Trouble codeC5358
RankB
Detection timing<bizhub 454e>
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Fusing power supply cooling fan (FM12)
• Expansion control board (EXCB)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between FM12-EXCB CN6 for proper connection and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM12 operation checkEXCB CN6-1 (REM)EXCB CN6-3 (LOCK)23-T
4Replace FM12 (Part# 4139M10000)
5EXCB ICP1 conduction check
6Replace EXCB (Part# A5AYH00501)
7Replace PRCB (554e Part# A61EH00101 / 454e Part# A61DH00101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.7 (Link to the Field Service Manual)