How Can We Help?

C5358 (bizhub C554/C454)

You are here:

Contents

Trouble typeFusing power supply cooling fanâ??s failure to turn <bizhub C454>
Trouble codeC5358
RankB
Detection timing<bizhub C454>
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary.
Trouble isolation
Relevant electrical parts-Fusing power supply cooling fan (FM12)
-Expansion control board (EXCB)
-Printer control board (PRCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between FM12-EXCB CN6 for proper connection and correct as necessary.
2Check the fan for possible overload and correct as necessary.
3FM12 operation checkEXCB CN6-1 (REM)EXCB CN6-3 (LOCK)23-T
4Replace FM12 (Part# 4139M10000)
5EXCB ICP1 conduction check
6Replace EXCB (Part# A2XKH00502)
7Replace PRCB (A4FJH00104)

K3.10.7 (Link to the Field Service Manual)

Table of Contents