C5360 (bizhub 368/308)
Contents
Trouble type | C5360: Clean unit fan failure to turn (When CU-101 is installed) |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • Exhaust fan 1 (FM14) • Exhaust fan 2 (FM15) • Suction fan (FM16) • Clean unit drive board (CUDB) • MFP board (MFPB) |
Procedure
- Check the connector between CUDB CN1-MFPB CN32E for proper connection and correct as necessary.
- Check the connector between FM14-CUDB CN3, FM15-CUDB CN2, FM16-relay CN183-CUDB CN4 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM14, FM15, FM16 operation check
- Load check: Check code42, Multi code 4
- Control signal: CUDB CN3 (FM14), CUDB CN2 (FM15), CUDB CN4 (FM16)
- Location of electrical component: 14-X
- Replace the defective fan. (FM14 Part# ? / FM15 Part# ? / FM16 Part# ?)
- Replace CUDB. (Part# ?)
- MFPB ICP14E conduction check
- Replace MFPB. (Part# A9HJH02102)
NOTICE
- Link to the wiring diagram (bizhub 368/308)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.16.3 (Link to the Field Service Manual)