How Can We Help?

C5360 (bizhub C4050i/C3350i)

You are here:

Contents

Trouble typeC5360: Clean unit fan failure to turn (When CU-202 is installed) (Europe models only)
RankB
Trouble detection conditionThe fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts• Exhaust fan/1 (FM1)
• Exhaust fan/2 (FM2)
• Exhaust fan/3 (FM3)
• Clean unit drive board (CUDB)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check the connector between CUDB CN1-relay CN35-BASEB CN25E for proper connection and correct as necessary.
  2. Check the connector between FM1-relay CN101-CUDB CN2 for proper connection and correct as necessary.
  3. Check the connector between FM2-relay CN102-CUDB CN2 for proper connection and correct as necessary.
  4. Check the connector between FM3-relay CN103-CUDB CN2 for proper connection and correct as necessary.
  5. Check the fan for possible overload and correct as necessary.
  6. Check CPUB for proper installation and correct as necessary.
  7. FM1 load check
    • Check code: 42
    • Multi code: 9, 10
    • Control signal: CUDB CN2-1 (REM), CUDB CN2-3 (LOCK)
    • Location of electrical component: 27-L
  8. FM2 load check
    • Check code: 42
    • Multi code: 9, 10
    • Control signal: CUDB CN2-4 (REM), CUDB CN2-6 (LOCK)
    • Location of electrical component: 28-L
  9. FM3 load check
    • Check code: 42
    • Multi code: 9, 10
    • Control signal: CUDB CN2-7 (REM), CUDB CN2-9 (LOCK)
    • Location of electrical component: 28-L
  10. Replace the defective fan. (FM1 ( A93EM10000 )/ FM2(
    A93EM10600 ) / FM3 ( A93EH01004 )
  11. Replace CUDB. CU-202 *5: Europe only
  12.  Replace CPUB. ( A93EH01004 )
  13. Replace BASEB. ( A93EH02007 )

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) L.3.10.3.

Table of Contents