How Can We Help?
C5360 (bizhub C4050i/C3350i)
Contents
Trouble type | C5360: Clean unit fan failure to turn (When CU-202 is installed) (Europe models only) |
Rank | B |
Trouble detection condition | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • Exhaust fan/1 (FM1) • Exhaust fan/2 (FM2) • Exhaust fan/3 (FM3) • Clean unit drive board (CUDB) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Check the connector between CUDB CN1-relay CN35-BASEB CN25E for proper connection and correct as necessary.
- Check the connector between FM1-relay CN101-CUDB CN2 for proper connection and correct as necessary.
- Check the connector between FM2-relay CN102-CUDB CN2 for proper connection and correct as necessary.
- Check the connector between FM3-relay CN103-CUDB CN2 for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM1 load check
- Check code: 42
- Multi code: 9, 10
- Control signal: CUDB CN2-1 (REM), CUDB CN2-3 (LOCK)
- Location of electrical component: 27-L
- FM2 load check
- Check code: 42
- Multi code: 9, 10
- Control signal: CUDB CN2-4 (REM), CUDB CN2-6 (LOCK)
- Location of electrical component: 28-L
- FM3 load check
- Check code: 42
- Multi code: 9, 10
- Control signal: CUDB CN2-7 (REM), CUDB CN2-9 (LOCK)
- Location of electrical component: 28-L
- Replace the defective fan. (FM1 ( A93EM10000 )/ FM2(
A93EM10600 ) / FM3 ( A93EH01004 ) - Replace CUDB. CU-202 *5: Europe only
- Replace CPUB. ( A93EH01004 )
- Replace BASEB. ( A93EH02007 )
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
(Link to the Field Service Manual) L.3.10.3.