Trouble type | C5361: UFP scavenging fan/Fr failure to turn |
Rank | B |
Trouble detection condition | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -UFP scavenging fan/Fr (FM17) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between FM17-relay CN801-relay CN5-BASEB CN22E for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- FM17 load check
- Check code: 42
- Multi code: 12
- Control signal: BASEB CN22E-7 (REM), BASEB CN22E-9 (LOCK)
- Location of electrical component: 12-C
- Replace FM17. (Part# A93EM10600)
- Replace CPUB. (Part# ACV7H02P02)