Trouble typeC5361: UFP scavenging fan/Fr failure to turn
RankB
Trouble detection conditionThe fan lock signal remains Low for a predetermined continuous period of time while the fan is turning.
Trouble isolation
Relevant electrical parts-UFP scavenging fan/Fr (FM17)
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the connector between FM17-relay CN801-relay CN5-BASEB CN22E for proper connection and correct as necessary.
  2. Check the fan for possible overload and correct as necessary.
  3. Check CPUB for proper installation and correct as necessary.
  4. FM17 load check
    • Check code: 42
    • Multi code: 12
    • Control signal: BASEB CN22E-7 (REM), BASEB CN22E-9 (LOCK)
    • Location of electrical component: 12-C
  5. Replace FM17. (Part# A93EM10600)
  6. Replace CPUB. (Part# ACKNH02P03)
  7. Replace BASEB. (Part# ACKNH02101)