C5372 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | C5372: MFP control board CPU temperature failure | 
| Rank | C | 
| Trouble detection condition | Temperature failure of CPU on the CPU board was detected. | 
| Trouble isolation | – | 
| Relevant electrical parts | -CPU cooling fan (FM3) -CPU board (CPUB) -Base board (BASEB)  | 
Procedure
- Check the connector between FM3-BASEB CN17 for proper connection and correct as necessary.
 - Check the fan for possible overload and correct as necessary.
 - Check CPUB for proper installation and correct as necessary.
 - FM3 operation check
- Control signal: BASEB CN17-1 to 2
 - Location of electrical component: 21-I
 
 - Replace CPUB. (Part# AAJRH01005)
 - BASEB ICP1 conduction check
 - Replace BASEB. (Part# A93EH02007)
 
L.3.10.4 (Link to the Field Service Manual)