How Can We Help?

C5372 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeMFP control board CPU temperature failure
Trouble codeC5372
RankC
Detection timingTemperature failure of CPU on the MFP board was detected.
Trouble isolation
Relevant electrical parts• CPU cooling fan (FM104)
• MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Reboot the machine.
2Check the connector between FM104-MFPB PJ20 for proper connection and correct as necessary.
3Check the fan for possible overload and correct as necessary.
4FM104 operation checkMFPB PJ2015-S
5Replace FM104 Contact Konica Minolta technical support if this needs to be replaced.
6Replace MFPB (Part# A2X0H02015)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.10.8 (Link to the Field Service Manual)

Table of Contents