Trouble typeC5603: Front side board communication error
RankC
Trouble detection conditionCommunication error is detected in front side board.
Trouble isolation
Relevant electrical parts• Front side board (FRB)
• PH unit
• MFP board (MFPB)

 Procedure

  1. Reboot the machine.
  2. Check the connector between FRB CN5-PH unit for proper connection and correct as necessary.
  3. Check the connector between FRB CN2-MFPB CN10E for proper connection and correct as necessary.
  4. Replace FRB. (Part# A9HJH00501)
  5. Replace the PH unit. (Part# A9HJR70000)
  6. MFPB ICP8E conduction check
  7. Replace MFPB. (Part# A9HJH02102)