How Can We Help?

C5610 (bizhub 958/808)

You are here:

Contents

Trouble typeC5610: PH LD drive communication error
RankC
Trouble detection conditionLD drive write data and read data disagree with each other a predetermined number of consecutive times.
Trouble isolation
Relevant electrical parts• PH unit
• PH relay board (PHRYB)
• MFP board (MFPB)

 Procedure

  1. Reboot the machine.
  2. Check the connector between the PH unit-PHRYB CN8 for proper connection and correct as necessary.
  3. Check the connector between PHRYB CN1-MFPB CN6E for proper connection and correct as necessary.
  4. Replace the PH unit. (Part# A796R70500)
  5. Replace PHRYB. (Part# A796H00300)
  6. Replace MFPB. (Part# A796H02003)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.10 (Link to the Field Service Manual)

Table of Contents