C5610 (bizhub C4000i/C3300i)

You are here:

Contents

Trouble typeC5610: PH LD drive communication error
RankC
Trouble detection condition• LD drive write data and read data disagree with each other a predetermined number of consecutive times.
• Different PH unit is installed.
Trouble isolation
Relevant electrical parts• PH unit
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Reboot the machine.
  2. Check the connector between the PH unit-BASEB CN13 for proper connection and correct as necessary.
  3. Check CPUB for proper installation and correct as necessary.
  4. Replace the PH unit. (bizhub C4000i Part# AAJRR72000 / bizhub C3300i Part# AAJTR70100)
  5. Replace CPUB. (Part# AAJRH01005)
  6. Replace BASEB. (Part# AAJRH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.10.8 (Link to the Field Service Manual)