C5610 (bizhub C4050i/C3350i)
Contents
Trouble type | C5610: PH LD drive communication error |
Rank | C |
Trouble detection condition | • LD drive write data and read data disagree with each other a predetermined number of consecutive times. • Different PH unit is installed. |
Trouble isolation | – |
Relevant electrical parts | • PH unit • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Reboot the machine.
- Check the connector between the PH unit-BASEB CN13 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace the PH unit. (C4050i) AAJRR72000 )( C3350i)AAJTR70100 )
- Replace CPUB. ( A93EH01004 )
- Replace BASEB. ( A93EH02007 )
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
(Link to the Field Service Manual) L.3.10.8.