C6001 (bizhub 554e/454e)

You are here:

(1)Contents

Trouble typeDF related configuration error 1
Trouble codeC6001
RankC
Detection timingInconsistency in the configuration with the installed DF is detected on the main body.
Trouble isolation
Relevant electrical parts• DF control board (DFCB)
• Dual scan image processing board (DSIPB)
• MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the type of the installed DF and replace it if it is a wrong one.
2Check to see the [Service mode] -> [System2] -> [ADF settings] is correct. It corrects, when a model is different.
3Correct the harness connection between DFCB and DSIPB if faulty.
4Correct the harness connection between DSIPB and MFPB if faulty.
5Replace DFCB (Part# A3CEPP4900)
6Replace DSIPB (Part# A5C1H02A01)
7Replace MFPB (Part# A61FH02005)
  • Link to the layout drawings for related parts by each trouble code (S.96. C6001)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.1 (Link to the Field Service Manual)