Trouble type DF related configuration error 1
Trouble code C6001
Rank C
Detection timing Inconsistency in the configuration with the installed DF is detected on the main body.
Trouble isolation
Relevant electrical parts • DF control board (DFCB)
• Dual scan image processing board (DSIPB)
• MFP board (MFPB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the type of the installed DF and replace it if it is a wrong one.
2 Correct the harness connection between DFCB and DSIPB if faulty.
3 Correct the harness connection between DSIPB and MFPB if faulty.
4 Replace DFCBDFCB (Part# A3CKH00102)
5 Replace DSIPBDSIPB (Part# A5C1H02A01)
6 Replace MFPBMFPB (Part# A55VH02304)
  • Link to the layout drawings for related parts by each trouble code (S.90. C6001)

Document Information ID D0001104802 Revise ID R000003