How Can We Help?
C6001 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C6001: DF related configuration error 1 |
Rank | C |
Trouble detection condition | Inconsistency in the configuration with the installed DF is detected on the main body. |
Trouble isolation | – |
Relevant electrical parts | -DF control board (DFCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the type of the installed DF and replace it if it is a wrong one.
- Check the connector between DFCB CN12-relay CN3DF-BASEB CN9E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace DFCB. (Part# AAMPH00105)
- Replace CPUB. (Part# ACKNH02P03)
- Replace BASEB. (Part# ACKNH02101)