Trouble typeDF related configuration error 1
Trouble codeC6001
RankC
Detection timingInconsistency in the configuration with the installed DF is detected on the main body.
Trouble isolation
Relevant electrical parts-DF control board (DFCB)
-Dual scan image processing board (DSIPB)
-MFP board (MFPB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the type of the installed DF and replace it if it is a wrong one.
2Correct the harness connection between DFCB and DSIPB if faulty.
3Correct the harness connection between DSIPB and MFPB if faulty.
4Replace DFCB (Part# A3CKH00102)
5Replace DSIPB (Part# A161H02A00)
6Replace MFPB (Part# A2XKH02004)
  • Link to the layout drawings for related parts by each trouble code (S.90. C6001)

K.3.11.1 (Link to the Field Service Manual)