How Can We Help?

C6001 (bizhub C759/C659)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC6001: DF related configuration error 1
RankC
Trouble detection conditionInconsistency in the configuration with the installed DF is detected on the main body.
Trouble isolation
Relevant electrical parts-DF control board (DFCB)
-Dual scan image processing board (DSIPB)
-MFP board (MFPB)

 Procedure

  1. Check the type of the installed DF and replace it if it is a wrong one.
  2. Check the connector between DFCB CN12-relay CN47-MFPB CN1E for proper connection and correct as necessary.
  3. Check the connector between DSIPB CN1-MFPB CN24 for proper connection and correct as necessary.
  4. Replace DFCB. (Part# A782H0010A)
  5. Replace DSIPB. (Part# A8JEH02A00)
  6. Replace MFPB. (Part# A8JEH02002)

L.3.13.1 (Link to the Field Service Manual)

Table of Contents