C6104 (bizhub 368/308)

You are here:

Contents

Trouble typeC6104: Back side cleaning home sensor abnormality (initial) (When DF-704 is installed)
RankB
Trouble detection condition• The CIS cleaning sensor (PS7) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
• The CIS cleaning sensor (PS7) does not change from L to H even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
Trouble isolationScanner
Relevant electrical parts• CIS cleaning sensor (PS7)
• CIS cleaning motor (M5)
• DF control board (DFCB)

 Procedure

  1. Check if the opening and closing guide is firmly closed.
  2. Check the connector between M5-DFCB J9 for proper connection and correct as necessary.
  3. Check the connector of M5 for proper drive coupling and correct as necessary.
  4. Check the connector between PS7-DFCB J13 for proper connection and correct as necessary.
  5. PS7 I/O check, sensor check
    • Control signal: DFCB J13-3 (ON)
    • Location of electrical component: DF-704 1-G
  6. M5 operation check
    • Control signal: DFCB J9-1 to 4
    • Location of electrical component: DF-704 6-G
  7. Replace M5. (Part# A3CEPP4A01)
  8. Replace DFCB. (Part# A85GPP0M00)

NOTICE

  • Link to the wiring diagram (DF-704)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.18.4 (Link to the Field Service Manual)