How Can We Help?

C6104 (bizhub C368/C308/C258)

You are here:

Contents

Trouble typeC6104: Back side cleaning home sensor abnormality (initial) (When DF-704 is installed)
RankB
Trouble detection condition• The CIS cleaning sensor (PS7) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
• The CIS cleaning sensor (PS7) does not change from L to H even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
Trouble isolationScanner
Relevant electrical parts• CIS cleaning sensor (PS7)
• CIS cleaning motor (M5)
• DF control board (DFCB)

 Procedure

  1. Check if the opening and closing guide is firmly closed.
  2. Check the connector between M5-DFCB J9 for proper connection and correct as necessary.
  3. Check the connector of M5 for proper drive coupling and correct as necessary.
  4. Check the connector between PS7-DFCB J13 for proper connection and correct as necessary.
  5. PS7 I/O check, sensor check
    • Control signal: DFCB J13-3 (ON)
    • Location of electrical component: DF-704 1-G
  6. M5 operation check
    • Control signal: DFCB J9-1 to 4
    • Location of electrical component: DF-704 6-G
  7. Replace M5.(Part# A3CEPP4A01)
  8. Replace DFCB. (Part# A85GPP0M00)

NOTICE

  • Link to the wiring diagram (DF-704)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.18.5 (Link to the Field Service Manual)

Table of Contents