How Can We Help?

C6104 (bizhub C554e/C454e)

You are here:

Contents

Trouble typeBack side cleaning home sensor abnormality (initial)
Trouble codeC6104
RankB
Detection timing• The CIS cleaning sensor (PS7) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
• The CIS cleaning sensor (PS7) does not change from L to H even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.
Trouble isolationScanner
Relevant electrical parts• CIS cleaning sensor (PS7)
• CIS cleaning motor (M5)
• DF control board (DFCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check if the opening and closing guide is firmly closed.
2Check the connector between M5-DFCB J9 for proper connection, and correct as necessary.
3Check the connector of M5 for proper drive coupling, and correct as necessary.
4Check the connector between PS7-DFCB J13 for proper connection, and correct as necessary.
5PS7 I/O check, sensor checkDRCB J13-3 (ON)DF-701 1-G
6M5 operation checkDRCB J9-1 to 4DF-701 6-G
7Replace M5 (Part# A3CEPP4A01)
8Replace DFCB (Part# A3CEPP4900)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.4 (Link to the Field Service Manual)