C6105 (bizhub C364e/C284e/C224e)

You are here:

Contents

Trouble typeBack side cleaning home sensor abnormality (normal)
Trouble codeC6105
RankB
Detection timing<When DF-701 is installed>
At the time of operation other than the initial operation, the CIS cleaning sensor (PS7) error is detected.
Trouble isolationScanner
Relevant electrical parts• CIS cleaning sensor (PS7)
• CIS cleaning motor (M5)
• DF control board (DFCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check if the opening and closing guide is firmly closed.
2Check the connector between M5-DFCB J9 for proper connection, and correct as necessary.
3Check the connector of M5 for proper drive coupling, and correct as necessary.
4Check the connector between PS7-DFCB J13 for proper connection, and correct as necessary.
5PS7 I/O check, sensor checkDRCB J13-3 (ON)DF-701 1-G
6M5 operation checkDRCB J9-1 to 4DF-701 6-G
7Replace M5 (Part# A3CEPP4A01)
8Replace DFCB (Part# A3CEPP4900)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.4 (Link to the Field Service Manual)