C6751 (bizhub 650i/550i/450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C6751: CCD clamp/gain adjustment failure |
Rank | B |
Trouble detection condition | The adjustment value is 0 or 255 during a CCD clamp adjustment.The peak value of the output data is 64 or less during a CCD gain adjustment. |
Trouble isolation | Scanner |
Relevant electrical parts | -LED exposure unit -CCD unit -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between CCDB CN2-BASEB CN6 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Check for possible extraneous light and correct as necessary.
- Clean the lens, mirrors, CCD surface, and shading sheet if dirty.
- Correct reflective mirror of the scanner if faulty, or change scanner mirror. (Part# A0ED271200)
- Replace the CCD unit. (Part# AA7NR72500)
- Replace CPUB.
650i/550i (Part# AC74H02P03)
450i (Part# AC76H02P02) - Replace BASEB. (Part# AC74H02101)