C6751 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeCCD clamp/gain adjustment failure
Trouble codeC6751
RankB
Detection timing• The adjustment value is 0 or 255 during a CCD clamp adjustment.
• The peak value of the output data is 64 or less during a CCD gain adjustment.
Trouble isolationScanner
Relevant electrical parts• LED exposure unit (LA201)
• CCD board (CCDB)
• MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Correct the harness connection between CCDB and MFPB if faulty.
2Check for possible extraneous light and correct as necessary.
3Clean the lens, mirrors, CCD surface, and shading sheet if dirty
4Correct reflective mirror of the scanner if faulty, or change scanner mirror.
5Replace the CCD unit (Part# A2X0R72111)
6Replace MFPB (Part# A2X0H02015)
  • Link to the layout drawings for related parts by each trouble code (S.95. C6751)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.