Contents
Trouble type | C6751: CCD clamp/gain adjustment failure |
Rank | B |
Trouble detection condition | The adjustment value is 0 or 255 during a CCD clamp adjustment.The peak value of the output data is 64 or less during a CCD gain adjustment. |
Trouble isolation | Scanner |
Relevant electrical parts | CIS module (IR CIS)CPU board (CPUB)Base board (BASEB) |
Procedure
- Check the connector between IR CIS-BASEB CN6 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Check for possible extraneous light and correct as necessary.
- Replace IR CIS.
- Replace CPUB.
- Replace BASEB.
(Link to the Field Service Manual)