How Can We Help?

C6753 (bizhub 554e/454e)

You are here:

(1)Contents

Trouble typeASIC clock input error (back side)
Trouble codeC6753
RankC
Detection timingWhen starting the machine, verification on reading and writing the predetermined value for image processing ASIC on dual scan image processing board (DSIPB) was conducted, and verification failure was detected.
Trouble isolation
Relevant electrical parts• CIS moduleCIS
• Dual scan image processing board (DSIPB)
• MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Correct the harness connection between DF and DSIPB if faulty.
2Correct the harness connection between DSIPB and MFPB if faulty.
3Replace CIS (Part# A3CEM70000)
4Replace DSIPB (Part# A5C1H02A01)
5Replace MFPB (Part# A61FH02005)
  • Link to the layout drawings for related parts by each trouble code (S.102. C6753)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.8 (Link to the Field Service Manual)

Table of Contents