How Can We Help?

C6754 (bizhub C3320i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC6754: Offset adjustment failure (back side)
RankB
Trouble detection conditionAt the offset adjustment, adjustment is not completed even after the retry exceeds the predetermined number of times.
Trouble isolationScanner
Relevant electrical parts-DF CIS module (DF CIS)
-DF CIS relay board (DFCISRYB)
-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the connector between DF CIS-DFCISRYB CN1 for proper connection and correct as necessary.
  2. Check the connector between DFCISRYB CN2-BASEB CN5 for proper connection and correct as necessary.
  3. Check CPUB for proper installation and correct as necessary.
  4. Check for possible extraneous light and correct as necessary.
  5. Clean the back side reading glass and the shading sheet if dirty.
  6. Replace the DF CIS module assy. (Part# AAJPR70800)
  7. Replace DFCISRYB. (Part# AAJPH10100)
  8. Replace CPUB. (Part# AAJRH01005)
  9. Replace BASEB. (Part# A93EH02007)

L.3.11.8 (Link to the Field Service Manual)

Table of Contents