Trouble type | C6754: CIS clamp adjustment failure (When DF-714 is installed) |
Rank | B |
Trouble detection condition | After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low. |
Trouble isolation | Scanner |
Relevant electrical parts | • CIS module (CIS) • CIS power supply (CISPU) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Check the connector between CIS J221-BASEB CN5 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Correct the harness connection between CIS J222-CISPU J2 if faulty.
- Check for possible extraneous light and correct as necessary.
- Clean the back side reading glass and the shading sheet if dirty.
- Replace CIS. (Part# AAMNM70000)
- Replace CISPU. (Part# A3CEPP4Y00)
- Replace CPUB. (Part# AA2JH02N06)
- Replace BASEB. (Part# AA2JH02005)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.