Trouble typeC6901: DSC board mount failure 1
RankC
Trouble detection conditionIn [Service Mode] -> [System 2] -> [Option Board Status], the DSC1 is set to [Set].
Since the DSC board cannot be mounted in this machine, the DSC1 and DSC2 must be normally set to [Unset].
Trouble isolation
Relevant electrical parts

 Procedure

  1. In [Service Mode] -> [System 2] -> [Option Board Status], set the DSC1 and DSC2 to [Unset].
  2. Turn OFF the main power switch, disconnect and then connect the power cord. Wait for 10 sec. or more after connect the power cord, and turn ON the main power switch.