C6902 (bizhub 554e/454e)

You are here:

Contents

Trouble typeDSC board bus check NG1-1, DSC board bus check NG1-2
Trouble codeC6902
RankC
Detection timingWhen DSC bus check (front side) detects an error.
Trouble isolation
Relevant electrical parts• DSC board/1 (DSCB/1: SC-508)
• MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Correct the harness connection of DSCB/1 if faulty.
2Replace DSCB/1 (Not sold in the U.S.)
3Replace MFPB (Part# A61FH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.11 (Link to the Field Service Manual)