C6911 (bizhub 368/308)
Contents
Trouble type | C6911: DSC board mount failure 2 (When DF-704 + SC-508 is installed) |
Rank | C |
Trouble detection condition | When MFP detects that DSC board 2 (back side) is not properly installed |
Trouble isolation | – |
Relevant electrical parts | • DSC board 2 (DSCB/2; SC-508) • Dual scan image processing board (DSIPB; DF-704) • MFP board (MFPB) |
Procedure
- Correct the harness connection of DSCB/2 if faulty.
- Correct the harness connection of DSIPB if faulty.
- Replace DSCB/2. (Part# N/A)
- Replace DSIPB. (Part# N/A)
- Replace MFPB. (Part# A9HJH02102)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.