Trouble typeDSC Bus check NG2-1
Trouble codeC6912
RankC
Detection timingWhen DSC bus check (back side) detects an error.
Trouble isolation
Relevant electrical parts-DSC board/2 (DSCB/2; SC-508)
-Dual scan image processing board (DSIPB)
-MFP board (MFPB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Correct the harness connection of DSCB/2 if faulty.
2Correct the harness connection of DSIPB if faulty.
3Replace DSCB/2 (SC-508 Not sold in the U.S.)
4Replace DSIPB (Part# A161H02A00)
5Replace MFPB (Part# A2XKH02004)

K.3.11.12 (Link to the Field Service Manual)