How Can We Help?

C6913 (bizhub C364e/C284e/C224e)

You are here:

Contents

Trouble typeDSC Bus check NG2-1, DSC Bus check NG2-2
Trouble codeC6913
RankC
Detection timing<When DF-701 is installed> 
When DSC bus check (back side) detects an error.
Trouble isolation
Relevant electrical parts• DSC board/2 (DSCB/2; SC-508) 
• Dual scan image processing board (DSIPB) 
• MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Correct the harness connection of DSCB/2 if faulty.
2Correct the harness connection of DSIPB if faulty.
3Replace DSCB/2 (Contact Konica Minolta technical support if this needs to be replaced.)
4Replace DSIPB (Part# A161H02A00)
5Replace MFPB (Part# A5C1H0200B)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.12 (Link to the Field Service Manual)