C6913 (bizhub C658/C558/C458)
Contents
Trouble type | C6913: DSC Bus check NG2-2 (When SC-508 is installed) |
Rank | C |
Trouble detection condition | When DSC bus check (back side) detects an error. |
Trouble isolation | – |
Relevant electrical parts | • DSC board2 (DSCB/2; SC-508) • Dual scan image processing board (DSIPB) • MFP board (MFPB) |
Procedure
- Correct the harness connection of DSCB/2 if faulty.
- Correct the harness connection of DSIPB if faulty.
- Replace DSCB/2. (Replace SC-508 DCSB/2)
- Replace DSIPB. (Part# A79JH02A01)
- Replace MFPB. (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.18.17 (Link to the Field Service Manual)