How Can We Help?

C6913 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeDSC Bus check NG2-1, DSC Bus check NG2-2
Trouble codeC6913
RankC
Detection timingWhen DSC bus check (back side) detects an error.
Trouble isolation
Relevant electrical parts• DSC board/2 (DSCB/2; SC-508) 
• Dual scan image processing board (DSIPB) 
• MFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Correct the harness connection of DSCB/2 if faulty.
2Correct the harness connection of DSIPB if faulty.
3Replace DSCB/2 (SC-508 Not Sold in the U.S.)
4Replace DSIPB (Part# A5C1H02A01)
5Replace MFPB (Part# A2X0H02015)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.11.12 (Link to the Field Service Manual)

Table of Contents