Trouble typeC6F01: Scanner sequence trouble 1

C6F02: Scanner sequence trouble 2

C6F03: Scanner sequence trouble 3

C6F04: Scanner sequence trouble 4

C6F05: Scanner sequence trouble 5

C6F06: Scanner sequence trouble 6

C6F07: Scanner sequence trouble 7

C6F08: Scanner sequence trouble 8

C6F09: Scanner sequence trouble 9

C6F0A: Scanner sequence trouble 10

C6FDC: Scanner sequence trouble DC

C6FDD: Scanner sequence trouble DD
RankC6F01 to C6F0A: C

C6FDC, C6FDD: B
Trouble detection conditionThe original transport interval becomes shorter than the predetermined value due to an original transport control error in original reading in DF.
Trouble isolationScanner
Relevant electrical parts-CPU board (CPUB)
-Base board (BASEB)
-DF control board (DFCB)

Procedure

  1. Correct the cable connection between BASEB CN6E-DFCB CN9 if faulty.
  2. Check CPUB for proper installation and correct as necessary.
  3. Replace DFCB. (Part# A93EH00901)
  4. Replace CPUB. (Part# ACT9H01003)
  5. Replace BASEB.
    4750i (Part# ACT9H02013)
    4050i (Part# ACT9H02002)

(Link to the Field Service Manual)