How Can We Help?

C6F01,C6F02,C6F03,C6F04,C6F05,C6F06,C6F08,C6F07,C6F08,C6F09,C6F0A,C6FCD,C6FDD (bizhub 950i/850i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble type– C6F01: Scanner sequence trouble 1

– C6F02: Scanner sequence trouble 2

– C6F03: Scanner sequence trouble 3

– C6F04: Scanner sequence trouble 4

– C6F05: Scanner sequence trouble 5

– C6F06: Scanner sequence trouble 6

– C6F07: Scanner sequence trouble 7

– C6F08: Scanner sequence trouble 8

– C6F09: Scanner sequence trouble 9

– C6F0A: Scanner sequence trouble 10

– C6FDC: Scanner sequence trouble DC

– C6FDD: Scanner sequence trouble DD
Rank– C6F01 to C6F0A: C
– C6FDC, C6FDD: B
Trouble detection conditionThe original transport interval becomes shorter than the predetermined value due to an original transport control error in original reading in DF.
Trouble isolationScanner
Relevant electrical parts– CPU board (CPUB)
– Base board (BASEB)
– DF control board (DFCB)

Procedure

  1. Correct the harness connection between main body and DF if faulty.
  2. Check CPUB for proper installation and correct as necessary.
  3. Replace DFCB.
  4. Replace CPUB.
  5. Replace BASEB.

(Link to the Field Service Manual)

Table of Contents