Trouble typeC6F05: Scanner sequence trouble 5
RankC
Trouble detection conditionThe original transport interval becomes shorter than the predetermined value due to an original transport control error in original reading in DF.
Trouble isolationScanner
Relevant electrical parts-CPU board (CPUB)
-Base board (BASEB)
-DF control board (DFCB)

Procedure

  1. Correct the cable connection between BASEB CN6E-DFCB CN9 if faulty.
  2. Check CPUB for proper installation and correct as necessary.
  3. Replace DFCB. (Part# A93EH00901)
  4. Replace CPUB. (Part# AAJRH01005)
  5. Replace BASEB. (Part# A93EH02007)

L.3.11.11 (Link to the Field Service Manual)