C6F06 (bizhub C4050i/C3350i)
Contents
Trouble type | C6F06: Scanner sequence trouble 6 |
Rank | C |
Trouble detection condition | The original transport interval becomes shorter than the predetermined value due to an original transport control error in original reading in DF. |
Trouble isolation | Scanner |
Relevant electrical parts | • CPU board (CPUB) • Base board (BASEB) • DF control board (DFCB) |
Procedure
- Correct the cable connection between BASEB CN6E-DFCB CN9 if faulty.
- Check CPUB for proper installation and correct as necessary.
- Replace DFCB. (Part# A93EH00901)
- Replace CPUB. (Part# A93EH01004)
- Replace BASEB. (Part# A93EH02007)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.11.11 (Link to the Field Service Manual)