Trouble typeC6F07: Scanner sequence trouble 7
RankC
Trouble detection conditionThe original transport interval becomes shorter than the predetermined value due to an original transport control error in original reading in DF.
Trouble isolationScanner
Relevant electrical parts-CPU board (CPUB)
-Base board (BASEB)
-DF control board (DFCB)

Procedure

  1. Correct the harness connection between main body and DF if faulty.
  2. Check CPUB for proper installation and correct as necessary.
  3. Replace DFCB. (Part# AAMPH00105)
  4. Replace CPUB. (C650i Part# AA7NH02P03 / C550i Part# AA7PH02P01 / C450i Part# AA7RH02P02)
  5. Replace BASEB. (Part# AA7NH02102)

L.3.13.12 (Link to the Field Service Manual)