C7107 (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7107: ADU transport motor/1 failure |
Rank | C |
Trouble detection condition | After starting the motor, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -ADU transport motor/1 (M5) -Base board (BASEB) |
Procedure
- Check the connector between M5-relay CN86-BASEB CN18E for proper connection and correct as necessary.
- Check the connector of M5 for proper drive coupling and correct as necessary.
- M5 conduction check.
- Control signal: BASEB CN18E-7 to 10
- Location of electrical component: 6-C
- Replace M5. (Part# A2X0M10600)
- Replace BASEB. (Part# AA7NH02102)
L.3.14.2 (Link to the Field Service Manual)