Trouble type | C7135: Toner supply motor/Y failure |
Rank | C |
Trouble detection condition | After starting the motor, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -Toner supply motor/Y (M9) -Expansion control board (EXCB) |
Procedure
- Check the connector between M9-EXCB CN11EX for proper connection and correct as necessary.
- Check the connector of M9 for proper drive coupling and correct as necessary.
- M9 conduction check.
- Control signal: EXCB CN11EX-9 to 12
- Location of electrical component: 16-P
- Replace M9. (Part# A7PUM10600)