How Can We Help?
C7162 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7162: Tray 2 vertical transport motor failure |
Rank | B |
Trouble detection condition | After starting the motor, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -Tray 2 vertical transport motor (M23) -Base board (BASEB) |
Procedure
- Check the connector between M23-BASEB CN31E for proper connection and correct as necessary.
- Check the connector of M23 for proper drive coupling and correct as necessary.
- M23 conduction check.
- Control signal: BASEB CN31E-5 to 8
- Location of electrical component: 23-K
- Replace M23. (Part# A61DM10000)
- Replace BASEB. (Part# ACV7H02101)