Trouble type | C7163: Registration motor failure |
Rank | B |
Trouble detection condition | After starting the motor, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -Registration motor (M24) -Base board (BASEB) |
Procedure
- Check the connector between M24-BASEB CN31E for proper connection and correct as necessary.
- Check the connector of M24 for proper drive coupling and correct as necessary.
- M24 conduction check.
- Control signal: BASEB CN31E-9 to 12
- Location of electrical component: 24-K
- Replace M24. (Part# AA6RM10500)
- Replace BASEB. (Part# ACKNH02101)