C7206 (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7206: Bypass tray paper feed clutch failure |
Rank | C |
Trouble detection condition | After starting the clutch, an error is detected for the malfunction detection signal. |
Trouble isolation | Manual |
Relevant electrical parts | -Bypass tray paper feed clutch (CL7) -Base board (BASEB) |
Procedure
- Check the connector between CL7-relay CN20-relay CN13-BASEB CN26E for proper connection and correct as necessary.
- Check the connector of CL7 for proper drive coupling and correct as necessary.
- CL7 conduction check.
- Control signal: BASEB CN26EA-12 (ON)
- Location of electrical component: 10-K
- Replace CL7. (Part# A02E595100)
- Replace BASEB. (Part# AA7NH02102)
L.3.14.19 (Link to the Field Service Manual)