Trouble typeC720A: Registration clutch failure
RankC
Trouble detection conditionAfter starting the clutch, an error is detected for the malfunction detection signal.
Trouble isolation
Relevant electrical parts-Registration clutch (CL4)
-(Part# ACTAH02014)Base board (BASEB)

Procedure

  1. Check the connector between CL4-relay CN45-BASEB CN22E for proper connection and correct as necessary.
  2. Check the connector of CL4 for proper drive coupling and correct as necessary.
  3. CL4 conduction check
    • Control signal: BASEB CN22EA-3 (ON)
    • Location of electrical component: 12-C
  4. Replace CL4. (Part# A7AHM20501)
  5. Replace BASEB.(Part# ACTAH02014)