Contents
Trouble type | C720F: ADU reverse rotation clutch failure |
Rank | C |
Trouble detection condition | After starting the clutch, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | ADU reverse rotation clutch (CL7)Base board (BASEB) |
Procedure
- Check the connector between CL7-relay CN39-BASEB CN18E for proper connection and correct as necessary.
- Check the connector of CL7 for proper drive coupling and correct as necessary.
- CL7 conduction check
- Control signal: BASEB CN18E-7 (ON)
- Location of electrical component: 3-C
- Replace CL7.
- Replace BASEB.
(Link to the Field Service Manual)