C7302 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C7302: Transfer belt cleaner cooling fan failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -Transfer belt cleaner cooling fan (FM2) -Expansion control board (EXCB) |
Procedure
- Check the connector between FM2-relay CN115-EXCB CN10EX for proper connection and correct as necessary.
- Check the connector of FM2 for proper drive coupling and correct as necessary.
- FM2 conduction check.
- Control signal: EXCB CN10EX-9 (REM), EXCB CN10EX-11 (LOCK)
- Location of electrical component: 22-P
- Replace FM2. (Part# A93EM10000)
- Replace EXCB. (Part# AC74H00501)