Contents
Trouble type | C7305: Paper cooling fan failure |
Rank | C |
Trouble detection condition | After starting the fan, an error is detected for the malfunction detection signal. |
Trouble isolation | – |
Relevant electrical parts | -Paper cooling fan (FM8) -Expansion control board (EXCB) |
Procedure
- Check the connector between FM8-relay CN27-relay CN28-EXCB CN14EX for proper connection and correct as necessary.
- Check the connector of FM8 for proper drive coupling and correct as necessary.
- FM8 conduction check.
- Control signal: EXCB CN14EX-1 (REM), EXCB CN14EX-3 (LOCK)
- Location of electrical component: 17-P
- Replace FM8. (Part# A93EM10600)
- Replace EXCB. (Part# AA7NH00500)